1 RU BlowerPanel, 100 CFM, 32dB
1 RU active blower panel providing 100 CFM of airflow with quiet 32 dB operation and proportional thermostatic control
The Middle Atlantic QBP-2 is a 1 RU active blower panel designed to manage heat within equipment racks using high static pressure proprietary blowers. This unit provides 100 CFM of airflow while maintaining a quiet operating level of only 32 dB at maximum. To ensure efficient thermal management, the QBP-2 features proportional thermostatic control, which allows the fans to run only when necessary based on ambient temperature. This compact design occupies only a single rack unit of space and features a brushed and anodized finish. The active component operates on 12 VDC power and is UL Listed for safety. With a width of 19 in (48.3 cm) and a depth of 10.1 in (25.7 cm), this panel provides a high-performance cooling solution for sensitive professional AV equipment within a standard 19-inch rack configuration.
Specifications are supplied by the manufacturer. For complete details, check the Resources section.Key features
Specifications
Main specifications 8
| AC Voltage Input | 120 |
| CFM | 100 |
| Depth | 10.1 in (25.7 cm) |
| Height | 1.75 in (4.4 cm) |
| Rack Units | 1 RU |
| Shipping Weight | 5.2 lbs (2.4 kg) |
| Volts DC | 12 VDC |
| Width | 19 in (48.3 cm) |
All other specifications 9
| Available Internationally | No |
| Component Type | Active |
| Finish | Brushed and Anodized |
| Manufacturer | Middle Atlantic |
| Mounting Points | 2 |
| Power Type | DC |
| TAA Compliant | No |
| UPC | 656747182228 |
| Certifications | UL Listed |
Resources
Questions about this part
How does the QBP-2 manage fan speed?
The unit uses proportional thermostatic control to adjust operation, ensuring it only runs when necessary to maintain appropriate temperatures.
What is the noise level of the QBP-2 during operation?
This blower panel is designed for quiet operation, producing only 32 dB while moving 100 CFM of air at its maximum setting.
Is the Middle Atlantic QBP-2 UL listed?
Yes, the QBP-2 is UL Listed and operates on 12 VDC power.
What are the physical dimensions of the QBP-2?
The unit is 1 RU in height (1.75 in or 4.4 cm), 19 in (48.3 cm) wide, and 10.1 in (25.7 cm) deep.
Which technical documents are available for the QBP series?
Installers can access the QBP Series Instruction Sheet, the A&E Specification Sheet, and CAD Technical Specification Drawings.